Acoustic resonance of the suction pipe intensifies cavitation

E44-237 · Pump Selection & Cavitation · Combined Reciprocating and Centrifugal System Pump IS125-100-200 · ★★

Problem Symptom

The natural frequency of the suction pipe was close to the excitation frequency, the pressure pulsated by plus or minus 0.02MPa and the trough values triggered cavitation

Root Cause

[Cavitation] Pressure pulsation resonance in the suction pipe drives the instantaneous pressure trough below Pv, producing pulsating cavitation.
[Calculation] The acoustic natural frequency of the pipe f is about c/4L and was close to the pump excitation frequency, so the pulsation trough Pmin fell below Pv and cavitation occurred.
[Design Omission] No acoustic check was made on the suction piping and the resonance was not avoided, so pulsating cavitation occurred.

Correct Solution

1) Adjust the suction pipe length to move the resonance frequency away: f is about c/4L and depends on L, so this avoids the resonance;
2) Fit a pulsation damping vessel (bladder type) on the suction side: the damper absorbs the pulsation, so the amplitude falls;
3) Increase the suction pipe volume to reduce the pulsation amplitude: a larger volume slows the pulsation, so the pressure is steadier;
4) Check the acoustic natural frequency of the system: avoiding the resonance requires knowing f, so this informs the design;
5) Raise the overall NPSHa to leave a margin for the pulsation: so that the trough does not fall below Pv, cavitation does not occur;
6) Monitor the amplitude of the inlet pressure pulsation: pulsation is the precursor, so this provides a diagnostic;
7) Commission the pump and measure the pulsation amplitude and the inlet pressure against the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the acoustic check of the suction line in the design: the original resonance was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH