Oversized head selection overpressures the network and shifts the duty

E44-238 · Pump Selection & Cavitation · Circulation Pump IRG200-250 · ★★

Problem Symptom

The head was selected as 40m against 28m actually needed, so the network was overpressured to 0.6MPa, the terminal valves were noisy and the pump ran in the high-flow region with cavitation

Root Cause

[Cavitation] The oversized head selection overpressures the network and shifts the pump towards high flow, where the overpressure throttling and the high flow together cause cavitation.
[Calculation] The head margin of 12m moves the operating point to the right into high flow and NPSHr rises, while the network is forced to throttle and wastes energy.
[Design Omission] The head was not calculated carefully against the actual network resistance and was too large, so the network was overpressured and the duty off design.

Correct Solution

1) Recalculate the head against the actual network resistance and reselect: an oversized head overpressures the network and shifts the duty, so this matches the machine to the duty;
2) Where an oversized pump is already installed, trim the impeller diameter to reduce the head: as D falls H falls with D squared, so the operating point moves back into place;
3) Use variable speed to match the actual demand: reducing the speed reduces H, so the network pressure returns to normal;
4) Control the head margin to 10% or less: an excessive margin shifts the duty off design, so a moderate margin is applied;
5) Moving the operating point back lowers NPSHr: NPSHr varies with Q squared, so the cavitation is eliminated;
6) Fit differential pressure control at the network terminal to stabilise the pressure: overpressure causes noise, so the pressure is stabilised;
7) Commission the pump and measure the network pressure and the operating point against the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the selection of the head against the actual piping resistance in the design: the original excessive head was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH