No margin left at selection leaves the flow short

E44-239 · Pump Selection & Cavitation · Centrifugal Pump IS80-65-125 · ★★

Problem Symptom

The selected flow was exactly equal to the demand, and after the piping aged and the resistance rose the operating point moved left, so the flow fell 13% and did not meet the requirement

Root Cause

[Cavitation] With no margin at selection, the increased piping resistance moved the operating point left and the flow became insufficient.
[Calculation] As the piping aged lambda rose and hf increased, the piping characteristic became steeper and the operating point moved left with Q falling from 1.0 to 0.87, with no margin to compensate.
[Design Omission] No flow margin was left at selection and the ageing of the piping was not taken into account, so the capability was insufficient.

Correct Solution

1) Leave a flow margin of 5 to 10% at selection: as the piping ages and the resistance rises, the machine still meets the requirement later in life;
2) Include the piping ageing factor when checking the operating point: lambda grows with the years of service, so the design looks ahead;
3) Reserve the option of trimming the impeller or varying the speed: the duty can be adjusted later, so the machine adapts to change;
4) Clean the line regularly to keep the resistance low: scaling raises the resistance, so the flow is kept steady;
5) Choose the operating point on the left side of the high-efficiency region, leaving room to move right: as the resistance rises the point moves right, so the region is not left;
6) Trend the flow and warn of decay: the fall is gradual, so it is acted on in time;
7) Commission the pump and verify the flow meets the requirement including the margin: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the flow margin and the ageing factor in the selection: the original absence of a margin was the root cause, so the design must always include it.