Very low inlet pressure in a vacuum system causes cavitation

E44-240 · Pump Selection & Cavitation · Vacuum System Transfer Pump IH50-32-160 · ★★★

Problem Symptom

Liquid was drawn from a vacuum vessel (-0.06MPa), so the inlet absolute pressure was only 0.04MPa, leaving NPSHa of 0.6m against NPSHr of 1.8m and severe cavitation

Root Cause

[Cavitation] Drawing from a vacuum system brings the inlet absolute pressure very low, so the Pa/rho*g term is tiny and NPSHa is seriously insufficient.
[Calculation] NPSHa=Pa/rho*g-Hs-hf-Pv/rho*g; with Pa only 0.04MPa the Pa/rho*g term is just 4m, and after all the deductions NPSHa is 0.6m against NPSHr.
[Design Omission] No ultra-low NPSHr pump was selected for the vacuum duty and the liquid level was not raised, so severe cavitation occurred.

Correct Solution

1) Select an ultra-low NPSHr pump (vertical can type or with inducer): NPSHa is extremely tight for vacuum duty, so the pump is matched to it;
2) Raise the vacuum vessel substantially or lower the pump elevation to increase Hz: the elevation difference is the main source of NPSHa, so this compensates;
3) Make the suction pipe as short and large-bore as possible to minimise hf: any pressure drop is fatal here, so the loss is reduced;
4) Control the medium temperature to lower Pv: Pv consumes further NPSHa, so the temperature is lowered;
5) Where necessary apply a modest pressurisation in the vessel to balance the absolute pressure: the absolute pressure is too low, so this raises Pa;
6) Install inlet pressure monitoring with a cavitation interlock: cavitation is very likely, so this protects the machine;
7) Commission the pump under the vacuum condition and measure the inlet pressure, confirming no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include a dedicated vacuum duty design in the procedure: the original lack of a dedicated design was the root cause, so the design must always include it.

Checklist