E44-487 · Filter Blockage and Fouling · Slurry Filter 200μm · ★★
Slurry settles on standing, cakes on the mesh surface, Δp=0.15MPa, fully blocked
[Mechanism] Solids settle onto the mesh and cake.
[Calculation] The settling velocity v_s raises the solids loading, pores shrink 50%, Δp=0.15.
[Design Omission] No circulation maintained and no mesh flushing; settling blockage results.
1) Maintain circulation upstream of the filter to prevent settling, because the original caked solids, 50% pore shrinkage and Δp=0.15 caused the blockage, so circulation prevents settling;
2) Add intermittent pulse flushing to the mesh surface, because buildup causes blockage, so pulse flushing is used;
3) Add agitation at the inlet to prevent settling, because standing still lets solids settle, so agitation is added;
4) Set a Δp alarm, because over-limit leads to dead blockage, so an alarm is provided;
5) Control slurry concentration to prevent thickening, because thick slurry settles readily, so concentration is controlled;
6) Lay piping at an incline to prevent stagnation, because stagnation causes settling, so inclined routing is used;
7) Regularly drain bottom sludge, because it builds up gradually, so sludge is drained;
8) Write circulation and mesh flushing into the slurry-filter specification, because the lack of circulation was the root cause of settling, so the slurry-filter spec governs.
GB/T 26114-2010 Liquid filters - Filters for filtration