E44-962 · Insufficient Vessel Strength and Wall Thickness · Vessel · ★★★
opening crack,weakness,leak
[Mechanism] Multiple openings cumulatively weaken the vessel without area reinforcement; the reinforcement area is less than the required area and the stress at the connections exceeds the limit and cracks.
[Calculation] Three DN100 openings require a reinforcement area of 5400 mm², but only 3000 mm² was provided, 44% short, so the stress was 1.8 times over.
[Design Omission] The total reinforcement was not calculated, no reinforcing pad was added and the stress was not checked.
1) Calculate the total reinforcement area A=Σ0.5dr²=5400 mm² (originally 3000); under-reinforcement raises the stress while making it up lowers it, thus restoring strength;
2) Verify the reinforcement is sufficient (actual ≥ required); insufficiency cracks while verifying it ensures safety, thus making the reinforcement compliant;
3) Add a full-ring reinforcing plate (12 mm thick covering 3 openings); individual reinforcement is weak while a full ring is strong, thus distributing the reinforcement;
4) Switch to a thicker shell δ=12 mm (originally 9 mm); a thin shell cracks while a thicker one strengthens it, thus reinforcing;
5) Perform radiographic testing (RT to detect lack of fusion); cracking first shows as a defect, enabling early repair, thus monitoring for cracks;
6) Perform a hydrostatic test (1.25 times design pressure); because the reinforcement calculation was omitted, verify no leakage by measurement, thus sizing the reinforcement from data;
7) Limit the number of openings to ≤3 and distribute them evenly; closeness weakens while even distribution evens it out, thus spacing openings evenly;
8) Write the reinforcement calculation and check into the calculation sheet; since the root cause of weakness is the omitted total reinforcement calculation, the calculation serves as a gate to prevent cracking.
GB/T 150.1-2011 Pressure vessels