E44-585 · Seal Leakage · Level Gauge Nozzle · ★★
Leakage, nozzle gasket loose
[Mechanism] A loose nozzle gasket causes the leakage.
[Calculation] The looseness leaves a gap that leaks.
[Design Omission] The joint was not tightened, no gasket was selected and nothing was inspected - it stayed loose.
1) Tighten the nozzle flange to a torque of 60N-m (diagonal); the original looseness left the specific pressure insufficient and it leaked, and raising the pressure stops the leak;
2) Select a corrosion-resistant gasket (PTFE or clad); corrosion makes it loose, and a corrosion-resistant material keeps it sound;
3) Align the nozzle to prevent eccentricity (assembly guides); an offset makes it loose, so alignment prevents it;
4) Add a Belleville spring washer to prevent loosening (disc springs); vibration causes loosening, and the spring washer prevents it;
5) Inspect the gasket condition (each maintenance shutdown); it loosens gradually and then leaks, so it is inspected;
6) Control the medium temperature (prevent thermal expansion loosening the joint); thermal expansion loosens it, so controlling the temperature prevents that;
7) Clean the face and remove rust before assembly; rust makes the joint loose, so cleaning the face prevents it;
8) Write the nozzle tightening into the assembly card; the original failure to tighten was the root cause of the looseness, so the assembly card closes the loop.
HG/T 21550-1993 Level Gauges