E44-586 · Seal Leakage · Thermocouple Thermowell · ★★
Leakage, thermowell seal not fully penetrated
[Mechanism] The thermowell seal was not fully penetrated by the weld and it leaks.
[Calculation] The lack of penetration leaves a gap that leaks.
[Design Omission] The weld was not fully penetrated, not inspected and not tested - the joint leaked.
1) Reweld the thermowell with full penetration (bevel, multi-pass); the original incomplete penetration left an unfused defect that leaked, and full penetration stops the leak;
2) Carry out a dye penetrant weld inspection (PT); without inspection the defect stayed and it leaked, so the weld is inspected;
3) Carry out a pneumatic leak test (0.1MPa hold); without the test the leak went undetected, so the test confirms tightness;
4) Select a matching filler wire (same base material); a dissimilar material cracks, so matching materials are chosen;
5) Control the weld heat to prevent distortion (symmetrical welding); distortion under a changing duty causes cracking, and controlling the heat prevents it;
6) Grind the root and remove slag (back gouging); slag prevents penetration, and cleaning the root ensures it;
7) Set a routine weld inspection (PT at every overhaul); cracks develop gradually and then leak, so the weld is inspected;
8) Write the full penetration and the leak test into the welding card; the original failure to weld was the root cause of the leak, so the welding card closes the loop.
GB/T 983-2012 Stainless Steel Covered Electrodes