E44-958 · Insufficient Vessel Strength and Wall Thickness · Vessel · ★★★
corrosion thinning,below minimum,leak
[Mechanism] The vessel was not given sufficient corrosion allowance for the corrosiveness of the media; in service the wall thinned below the minimum required thickness, losing strength and leaking.
[Calculation] The media contain 3% Cl-; corrosion is 0.3 mm/year and after 8 years of service the wall has thinned by 2.4 mm, leaving an actual thickness of 4.6 mm, below the required δ of 7 mm.
[Design Omission] No corrosion allowance was added, no periodic thickness inspection was set and no corrosion-resistant material was selected.
1) Recalculate the wall thickness including the corrosion allowance, δ=PCK/(2[σ]φ-P)+C with C=3 mm (originally C=0); an insufficient allowance lets thinning reach through-wall while adding allowance leaves thickness, thus restoring strength;
2) Verify the remaining wall thickness by ultrasonic measurement (≥7 mm at every point); thin walls lose strength while measuring thickness reveals the margin, thus monitoring thickness;
3) Switch to 316L corrosion-resistant material (originally Q235B); carbon steel corrodes fast while switching to stainless resists corrosion, thus preventing corrosion;
4) Perform periodic thickness measurement (every 6 months, keep a thickness log); thinning first shows as a drop in thickness, enabling early replacement, thus monitoring corrosion and preventing leaks;
5) Perform a hydrostatic test (1.25 times design pressure); because thinning and leakage were unverified, confirm no seepage by measurement, thus determining strength from data;
6) Line with rubber or apply a coating (3 mm thick); a bare wall corrodes while a lining isolates it, thus isolating the corrosion;
7) Keep the Cl- concentration ≤50 ppm in operation (treat if exceeded); the corrosion rate rises with concentration while controlling media quality suppresses corrosion, thus preventing thinning in operation;
8) Write the corrosion allowance and material selection into the calculation sheet; since the root cause of excessive thinning is the omitted corrosion allowance and the lack of inspection, the calculation serves as a gate to prevent leaks.
GB/T 150.1-2011 Pressure vessels