Knowledge Base › Fluid Systems Error Case › Vibration of an Unsupported Small-Bore Pipe

Vibration of an Unsupported Small-Bore Pipe

E44-814 · Piping Supports and Thermal Expansion · Small Bore · ★★

Problem Description

Small pipe unsupported, vibration >0.3mm, cracking

Root Cause

[Mechanism] An unsupported small pipe vibrates.
[Calculation] Without support the amplitude exceeds >0.3mm and the weld cracks by fatigue.
[Design Omission] No supports were designed or secured — so supports must be provided.

Corrective Solution

1) Add supports for the small pipe (fit clamp supports every 1.5-2m): because the original lack of support drove the amplitude >0.3mm and the weld cracked by fatigue, adding supports reduces vibration;
2) Check the support spacing (set the span ≤2m for small bore): because sparse supports vibrate and the check densifies them, the spacing is checked;
3) Add clamps to secure it (clamps grip the pipe to prevent slipping): because floating vibrates and clamps secure it, clamps are added;
4) Limit the flow velocity against vibration (velocity ≤0.5 Mach to prevent chatter): because too fast a flow vibrates and limiting relieves it, the velocity is limited;
5) Monitor the vibration condition (measure the amplitude, alarm >0.2mm): because progressive vibration brings cracking closer and early awareness helps, vibration is monitored;
6) Perform a load test (start up and check the vibration): because the original lack of testing left the vibration undiscovered, the test measures the amplitude, so the load test is run;
7) Control the excitation source (avoid the resonance frequency): because the source causes vibration and control relieves it, the source is controlled;
8) Write the added supports and spacing check into the assembly card: the original lack of supports was the root cause, so assembly controls the work and the small pipe does not vibrate.

Checklist

Reference

GB/T 17116.1-2018 Pipe supports and hangers