Knowledge Base › Fluid Systems Error Case › Thermal Expansion in a Hydrogen-Service Pipe

Thermal Expansion in a Hydrogen-Service Pipe

E44-815 · Piping Supports and Thermal Expansion · Hydrogen-Service Pipe · ★★★

Problem Description

Hydrogen-service pipe thermal expansion, stress > allowable, cracking

Root Cause

[Mechanism] Thermal expansion of the hydrogen-service pipe raises the stress.
[Calculation] Expansion drives the stress > the allowable and causes hydrogen-embrittlement cracking.
[Design Omission] Neither compensation nor supports were provided — so compensation must be added.

Corrective Solution

1) Install expansion joints to reduce the expansion (axial compensation absorbs the thermal expansion): because the original lack of compensation drove the stress > the allowable and caused hydrogen-embrittlement cracking, compensation reduces the stress;
2) Calculate the thermal displacement (ΔL=αLΔT, verify at each point): because the missing calculation let it exceed and the calculation reveals it, the displacement is calculated;
3) Check the allowable stress against hydrogen embrittlement (lower the allowable stress per NACE to prevent hydrogen-induced cracking): because embrittlement cracks and the check ensures compliance, the allowable is checked;
4) Add anchoring to carry the weight (anchor the supports against floating, distribute the load evenly): because floating cracks and anchoring stabilizes it, the supports are anchored;
5) Monitor the expansion condition (displacement / wall-thickness monitoring, with alarms): because progressive expansion brings cracking closer and early awareness helps, expansion is monitored;
6) Perform a hot test (raise the temperature and record the stress / displacement): because the original lack of testing left the stress undiscovered, the test identifies the loads, so the hot test is run;
7) Control the temperature to prevent rapid change (heating ≤30℃/h): because a rapid change cracks and a slow one keeps it under control, the temperature is controlled;
8) Write the compensation and displacement calculation into the calculation sheet: the original lack of compensation was the root cause of the expansion, so calculation controls the design and the hydrogen pipe is safe.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping