Cold Contraction in a Low-Temperature Pipe

E44-816 · Piping Supports and Thermal Expansion · Low-Temperature Pipe · ★★★

Problem Description

Low-temperature pipe contraction, tensile stress > allowable, cracking

Root Cause

[Mechanism] Cold contraction of the low-temperature pipe produces tensile stress.
[Calculation] Cold contraction drives the tensile stress > the allowable and cracks the weld.
[Design Omission] Neither compensation nor allowance was provided — so compensation must be added.

Corrective Solution

1) Install expansion joints to absorb the contraction (axial compensation absorbs the cold contraction): because the original lack of compensation drove the tensile stress > the allowable and cracked the weld, compensation reduces the tension;
2) Allow for the cold contraction (pre-stretch in the cold state as an allowance): because without it tension builds and the allowance relieves it, the allowance is provided;
3) Check the tensile stress (σ≤[σ], per the low-temperature material): because excessive stress cracks and the check ensures compliance, the tension is checked;
4) Add guides to limit deviation (guides at both ends keep alignment): because deviation causes tension and guides correct it, guides are added;
5) Monitor the contraction condition (displacement-mark monitoring, with alarms): because progressive contraction brings cracking closer and early awareness helps, contraction is monitored;
6) Perform a cold test (lower the temperature and record the displacement / stress): because the original lack of testing left the tension undiscovered, the test identifies the loads, so the cold test is run;
7) Control the temperature ramp rate (cooling ≤30℃/h): because a rapid change causes tension and a slow one keeps it under control, the rate is controlled;
8) Write the compensation and allowance into the calculation sheet: the original lack of compensation was the root cause of the contraction, so calculation controls the design and the cold pipe does not crack.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »