E44-029 · Uneven Flow Distribution · Reactor feed distribution pipe · ★★
A 40% flow difference between the holes of the distribution pipe, the reaction is uneven and the conversion is 8% low
[Orifice Flow] Different back pressures at the holes make the orifice velocity v = Cd√(2Δp/ρ) differ.
[Distribution] The near-end holes fight for flow and the far-end ones are starved, so the distribution is uneven.
[Design Omission] No even-orifice design and no pressure-drop splitting were provided, so the distribution difference makes it uneven.
1) Design the distribution pipe for equal pressure drop at each hole, because different back pressures make v = Cd√(2Δp/ρ) differ and create a 40% flow difference, thereby using equal pressure drop to even the hole flows;
2) Add fine-tuning orifices at the holes to even the flow, because they adjust the resistance of each hole and compensate the back-pressure difference, thereby distributing evenly;
3) Keep the friction pressure drop along the main pipe small (≤5%), because a large main-pipe drop lowers the far-end hole pressure and starves it, thereby controlling the drop and preserving the far-end pressure;
4) Lay out the distribution pipe symmetrically to reduce flow deviation, because symmetry equalizes the hole spacing and back pressures, thereby reducing the deviation;
5) Install multi-point flow meters to monitor each hole, because the individual hole flows are hard to observe, thereby monitoring at multiple points;
6) Simulate the flow field to validate uniformity, because the simulation exposes the flow deviation, thereby verifying first;
7) Measure at commissioning that the difference between holes is ≤10% (from 40%), because a small difference means an even distribution and a higher conversion, thereby performing acceptance;
8) Build the distribution design into the reactor process, because the missing pressure-drop splitting was the root cause of the distribution difference, so the process must include it.
GB/T 150-2011 Pressure vessels