E44-030 · Uneven Flow Distribution · Multi-pass shell-and-tube heat exchanger · ★★

Problem Description

Poor tube-side pass-partition sealing leaves some tubes at low velocity and fouling and others at high velocity and vibrating

Root Cause

[Pass Short-Circuiting] Poor partition sealing short-circuits the passes and reduces the effective number of tubes.
[Velocity Difference] The flow deviation leaves some tubes at v <1m/s prone to fouling and others at v >3 vibrating.
[Design Omission] Neither the pass-partition seal nor the per-pass resistance was checked, so the flow deviation causes the faults.

Corrective Solution

1) Design the pass-partition seal for a high pressure difference, because poor sealing short-circuits the passes, reduces the effective tube count, and deviates the flow, thereby sealing against short-circuiting at a high pressure difference;
2) Check that the passes have balanced resistance, because unequal resistance deviates the flow and leaves some tubes at v <1 prone to fouling or v >3 vibrating, thereby balancing the resistance and the flow;
3) Finish the mating surface between the tube sheet and the partition precisely, because a rough surface seals poorly and leaks, thereby finishing it to ensure sealing;
4) Keep the velocity in each tube at 1~2.5m/s, because an excessive velocity vibrates and a low one fouls, thereby controlling the velocity to gain both;
5) Provide per-pass pressure-drop monitoring, because an abnormal pressure drop signals short-circuiting, thereby giving early warning;
6) Add baffles in the shell to prevent short-circuiting, because the baffles guide the flow and reduce bypassing, thereby preventing the short circuit;
7) Measure the flow balance of each pass at commissioning, because a balanced flow means no deviation, thereby performing acceptance;
8) Build the pass-partition seal into the heat-exchanger drawings, because the missing seal control was the root cause of the short circuit, so the drawings must specify it.

Checklist

Reference

GB/T 151-2014 Heat exchangers