E44-555 · Seal Leakage · Water-Pump Mechanical Seal, Multi-Spring · ★★
Leak was 1.5L/h; three springs were broken, the face pressure was 0MPa, and contact was lost.
[Mechanism] Broken springs lose the face pressure.
[Calculation] Breaking 3 of 8 springs drops the face pressure to 0 <0.15MPa, and the faces part and leak.
[Design Omission] No corrosion-resistant springs, no spring protection, and no single-spring choice — rust-broken.
1) Replace with corrosion-resistant springs (Inconel X-750, Cl- resistance ≥200ppm); the original 304 springs pitted and broke 3 of 8 at Cl- >50ppm, dropping total spring load to 0MPa face pressure and leaking 1.5L/h, so corrosion-resistant springs do not break, restoring face pressure and stopping the leak;
2) Switch to a single large spring (1 spring replacing 8 small ones); in a multi-spring set any broken spring loses even pressure, while a single spring has higher redundancy, so raise reliable even loading;
3) Add spring protective sleeves against corrosion (PTFE sleeve isolating the medium); corrosion breaks them, so sleeve and protect the springs;
4) Correct the face pressure back to 0.2MPa (adjust spring preload); the original 0 pressure parted the faces and leaked, so restore pressure and contact;
5) Hold medium Cl- <50ppm (neutralization / material choice); high chloride corrodes and breaks springs, so control chloride to extend spring life;
6) Coat springs with a corrosion inhibitor (Dacromet) for protection; corrosion breaks them, so coat to extend life;
7) Periodically inspect for broken springs (every 3 months, magnetic-particle / visual); gradual breakage loses pressure, so inspect springs and warn;
8) Write corrosion-resistant springs into the spec; the unselected material was the break root cause, so gate the spec.
GB/T 14211-2019 Mechanical seals - Specifications