E44-1091 · Other · Drain Valve · ★★
Blocked, poor discharge, sluggish.
[Mechanism] Scale and sediment deposited inside the drain valve, shrinking the flow area to 30% of original; insufficient discharge left sediment stuck in the line and built up pressure.
[Calculation] The valve bore DN25, after scaling had an effective section of only DN14 (56% reduction); discharge Q=Av fell from 0.8m³/h to 0.35m³/h, below the 0.5m³/h sediment-generation rate, so sediment accumulated.
[Design Omission] No flushing line, no large bore, no cleaning interval set, and no differential-pressure alarm.
1) Provide a flushing line (0.3MPa steam purge each shift); deposition blocks, and purging clears it, restoring discharge;
2) Check the bore ≥DN40 (replacing DN25); a small bore blocks, and an adequate bore keeps it open, discharging freely;
3) Add a Y-strainer (80 mesh) upstream; sediment in blocks, and straining cleans it, preventing blockage;
4) Control full-opening discharge (≥30s); a half-open position deposits, and full opening cleans it;
5) Run a discharge test (≥0.8m³/h meets target); untested means unknown, and measured flow confirms it;
6) Install differential-pressure monitoring (alarm on ΔP>0.1); a blockage first shows as pressure rise, and early warning catches it;
7) Set a cleaning interval (weekly disassembly); long intervals block, and controlled intervals keep it clean;
8) Record flushing and bore on the drain drawing; the root cause of blockage was no flushing and a small bore, so the drawing must gate it.
GB/T 12238-2008 Valves