E44-1090 · Other · Metering Tank · ★★
Reading bias, batching, error.
[Mechanism] The metering tank was uncalibrated or the wall coated material; the reading biased and batching erred.
[Calculation] No calibration left a 3% reading bias; 5kg coated the wall; batching error 4%; product out of spec.
[Design Omission] No calibration, no wall cleaning, and no inspection.
1) Calibrate the metering accurately (weighted calibration); bias causes error, and calibration restores correct batching;
2) Clean wall coating (every batch); coating biases the reading, and cleaning makes it true;
3) Add temperature compensation (density compensation by temperature); temperature difference biases, and compensation makes it accurate;
4) Control viewing angle (vertical reading); an angle biases, and correct viewing makes the reading accurate;
5) Run a metering test (difference vs standard ≤1%); bias was unchecked, and measured accuracy confirms it;
6) Install weighing monitoring (alarm on bias); bias first shows as a weight difference, and early warning catches it;
7) Set a fixed calibration interval in operation (monthly); long intervals bias, and controlled intervals calibrate, preventing bias;
8) Record calibration and wall cleaning on the metering card; the root cause of metering bias was no calibration and wall coating, so the card must gate it.
GB/T 7723-2008 Stationary electronic weighing instruments