Clogged trash rack in the suction tank drops NPSHa and causes cavitation

E44-248 · Pump Selection & Cavitation · Vertical circulation pump 500ZLB · ★★

Problem Symptom

The trash rack in the suction tank was 60% clogged, the head loss through the rack rose to 0.8m, NPSHa fell and the pump cavitated and vibrated

Root Cause

[Cavitation] The clogged rack increases the head loss through the rack, locally lowers the water level in the suction tank and leaves NPSHa insufficient.
[Calculation] Clogging raises the velocity through the rack and Δh=ζv²/2g rises to 0.8m, so the effective submergence ahead of the pump falls and NPSHa becomes insufficient and cavitation occurs.
[Design Omission] The rack had no screen cleaning monitoring and no alarm on blockage, so the loss through the rack grew unchecked.

Correct Solution

1) Install a level difference monitor on the rack and clean the screen at regular intervals, because clogging increases the loss, thereby keeping it clear promptly;
2) Fit a mechanical rake cleaner to clean the screen automatically, because manual cleaning lags, thereby keeping the rack clean continuously;
3) Provide sufficient open area through the rack (a low approach velocity), because a large area gives a low velocity and a small loss, thereby keeping Δh small;
4) Alarm when the upstream and downstream level difference exceeds the limit, because the clogging is otherwise hidden, thereby giving early warning;
5) Check NPSHa for the half-blocked rack condition, because the dirtiest condition is the most severe, thereby covering the worst case;
6) Use pump vibration monitoring as an auxiliary cavitation indication, because cavitation causes vibration, thereby enabling diagnosis;
7) Simulate blockage during commissioning to verify that NPSHa is adequate, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate screen cleaning monitoring into the design, because the absence of monitoring was the root cause, so the design must include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH