Knowledge Base › Fluid Systems Error Case › Vessel Over-Temperature Deformation

Vessel Over-Temperature Deformation

E44-1000 · Vessel Strength and Wall-Thickness Deficiency · Pressure vessel · ★★★

Problem Description

Over-temperature, deformation, change

Root Cause

[Mechanism] Operating temperature exceeded the material's design temperature; modulus dropped, allowable stress fell, and the vessel plastically deformed.
[Calculation] t=300℃ vs design 200℃, E drops 12%, [σ] falls from 137 to 121MPa, required δ rises from 9.8 to 11.1mm, growth 4mm.
[Design Omission] No temperature limit, no design-temperature check, and no material upgrade.

Corrective Solution

1) Limit operating temperature ≤200℃ (cooling kicks in if exceeded), since over-temperature drops E and raises stress and the limit protects it — thus preventing deformation;
2) Set design temperature at peak operating +20℃ (was missed), since a low design temperature invites over-temperature and the correct temperature protects it — thus compliant temperature;
3) Upgrade the material grade (Q345R for Q235B, higher temperature rating), since a low grade deforms and a higher one raises allowable — thus raising strength;
4) Recalculate wall thickness for the actual temperature (δ needed 11.1mm, was 9.8mm), since high temperature raises stress and added thickness lowers it — thus restoring strength;
5) Fit a temperature transmitter plus alarm (alert at >200℃), since over-temperature first shows as a temperature change, before deformation — thus monitoring and warning early;
6) Run a high-temperature service test (250℃ held), since the design temperature was unchecked and measurement confirms stability — thus setting strength by data;
7) Hold heat-up/cool-down rate ≤30℃/h (sudden changes damage the part), since abrupt change causes stress and a slow rate is steady — thus operating smoothly;
8) Write the temperature limit and check into the calculation book, since the over-temperature deformation root cause was the missed limit and unchecked design temperature — thus locking it in at design.

Checklist

Reference

GB/T 150.1-2011 Pressure vessels