E44-1001 · Vessel Strength and Wall-Thickness Deficiency · Pressure vessel · ★★★
Missing stability calc, collapse, deformation
[Mechanism] The vessel was designed for internal pressure only, missing the external-pressure stability check; when operating vacuum occurred, the shell buckled and collapsed.
[Calculation] P_out=0.07MPa while the design was internal-pressure only, Pcr=0.03MPa (no stability check), exceeded by 133%, collapse depth 30mm.
[Design Omission] No external-pressure stability calc, no ring, and no vacuum breaker.
1) Add the external-pressure stability calc (Pcr≥1.5P_out=0.105MPa), since the missed calc caused Pcr=0.03 collapse and the stability calc protects it — thus preventing collapse;
2) Add stiffening rings (flat bar -80×8, two rings), since a weak shell collapses and a ring raises stiffness — thus stabilizing shape;
3) Raise the wall to 10mm (was 8mm), since a thin wall collapses and a thicker one raises stability — thus reinforcing;
4) Fit a vacuum breaker (opens on vacuum), since negative pressure collapses and breaking the vacuum balances it — thus preventing vacuum collapse;
5) Run an external-pressure test (0.105MPa held), since the collapse came from an unvalidated design and measurement confirms stability — thus setting stability by data;
6) Produce a stability check report (with B-curve Pcr lookup), since the missed calc had no basis and the added calc is standard — thus locking it in at design;
7) Hold operating vacuum ≤0.04MPa (break if exceeded), since a large vacuum collapses and control stabilizes — thus running to prevent collapse;
8) Write the stability calc and ring into the calculation book, since the missing-stability-calc root cause was the missed Pcr and missing ring — thus locking it in at design.
GB/T 150.1-2011 Pressure vessels