E44-330 · Excessive Piping Resistance and Pressure Drop · Compressed-Air Pipe with Low Points Undrained · ★★
Low-point pooling shrank the gas flow area 50%, doubled pressure drop, and dropped end pressure 0.12MPa.
[Pooling] Low-point liquid occupies the section, shrinking the gas path and raising resistance.
[Pressure Drop] Doubled pressure drop drops the end pressure 0.12.
[Design Omission] No automatic drain and no slope; pooling resistance was high.
1) Slope the pipe and add an automatic drain valve at low points; pooling occupied 50%, doubled drop, and dropped 0.12, so draining holds the gas area;
2) Slope ≥0.003 toward the drain point; a flat line easily pools, so lay it sloped;
3) Add a gas-liquid separator with periodic draining; liquid travels with gas, so separate it;
4) Fit a trap at the end; liquid gathers at the end, so drain there;
5) Check two-phase pressure drop with liquid; the pure-gas formula under-predicts, so compute accurately;
6) Vent high points and drain low points as double protection; both gas and liquid are hazards, so double-protect;
7) Periodically check for pooling; pooling gradually hardens to notice, so inspect for liquid;
8) Bring draining into the design; the original omission was the root cause of resistance, so the design must gate it.
GB/T 20801.3-2020 Design code for industrial metallic piping