MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Fluid System Error Cases › Blocked inlet filter on th
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Blocked inlet filter on the feed pump raises the pressure drop and causes cavitation

E44-155 · Pump Selection & Cavitation · Feed Pump Suction Y-Strainer · ★★

Problem Symptom

Blockage of the inlet Y-strainer produced a differential pressure of 0.05MPa, NPSHa fell, the impeller cavitated and the flow dropped 20%

Root Cause

[Blockage Drop] A blocked strainer increases the inlet pressure loss.
[Cavitation] NPSHa=Pa/rho*g-hf and so on drops, and cavitation follows.
[Design Omission] No differential pressure alarm was fitted to trigger strainer cleaning, so cavitation occurred.

Correct Solution

1) Fit a differential pressure alarm to the inlet filter and clean the strainer on the alarm: the blockage raises the differential pressure to 0.05MPa and lowers NPSHa until cavitation occurs, so early alarm and cleaning is required;
2) Select a filter of appropriate fineness so it does not clog too quickly: too fine a rating clogs readily, so the correct rating balances efficiency and life;
3) Enlarge the suction pipe diameter to lower velocity and reduce hf: a high velocity gives a high hf, so a larger diameter reduces the resistance;
4) Re-check NPSHa including the strainer resistance: the original design omitted the strainer resistance, so it is now included in the recalculation;
5) Inspect the strainer and keep it clean at regular intervals: it clogs progressively, so regular inspection is needed;
6) Fit an air vent at the pump inlet to prevent an air lock: air accompanies the blockage, so venting is required;
7) Commission the pump and verify the flow recovers to the design value: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the strainer resistance in the cavitation check: the original omission was the root cause of the reduced margin, so the check must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal, Mixed-Flow and Axial-Flow Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL