E44-154 · Pump Selection & Cavitation · Light Hydrocarbon Transfer Pump · ★★★
Light hydrocarbon with a saturation vapour pressure of 0.12MPa was pumped with no pressure tank provided; flash evaporation at the inlet cavitated the pump and cracked the casing
[Flash Evaporation] The saturation vapour pressure of the medium is close to the inlet pressure, so flash evaporation causes cavitation.
[Calculation] The inlet pressure P=0.15 is below Pv plus the differential pressure, so a vapour phase forms.
[Design Omission] No pressurised seal tank was provided to raise the inlet pressure, so cavitation occurred.
1) Provide a pressure tank for the easily vaporised medium to raise the inlet pressure above Pv plus the differential pressure: the saturation vapour pressure is close to the inlet pressure and flash evaporation follows, so pressurising stops the vapour formation;
2) Provide inlet cooling to lower the vapour pressure of the medium: a high temperature encourages vaporisation, so cooling stabilises the duty;
3) Select a cavitation-resistant pump type with a low NPSHr: the cavitation threshold is then low, so the demand is small and the duty is stable;
4) Keep the suction pipe short and straight to limit the resistance and preserve NPSHa: added resistance reduces the margin, so a short straight run protects it;
5) Install a pressure interlock on the seal tank: a pressure drop causes flash evaporation, so the interlock preserves the pressure;
6) Monitor the vibration to identify cavitation: cavitation produces a distinctive vibration, so this gives early warning;
7) Trial-run to verify cavitation-free delivery at the rated flow: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the pressurisation design in the selection for easily vaporised media: the original absence of pressurisation was the root cause of the flash evaporation, so selection must always include it.
GB/T 13006-2013 Centrifugal, Mixed-Flow and Axial-Flow Pumps - NPSH