E44-153 · Pump Selection & Cavitation · Double-Suction Centrifugal Pump · ★★
After 2 years of running the back vanes had worn away, cavitation craters 2mm deep formed at the inlet, and the flow dropped from 200m3/h to 165m3/h
[Back Vane Wear] Worn-away back vanes remove the pre-rotation pressurisation at the inlet.
[Cavitation] The reduced NPSHa allows bubbles to collapse and erode the metal.
[Design Omission] No wear-resistant back vanes were fitted and the wear was never inspected at intervals, so the cavitation worsened.
1) Re-check NPSHa to at least NPSHr+0.5 and retain a margin: the worn back vanes have lost the inlet pressurisation and cavitation follows, so the recalculation protects the margin;
2) Select an impeller with wear-resistant back vanes or reinforce them: the back vane wear must be arrested, so a wear-resistant construction extends the life;
3) Fit an inducer at the inlet to improve cavitation resistance: the NPSHa margin is marginal, so the inducer stabilises the machine;
4) Open the pump at regular intervals to inspect back vane wear: the wear grows gradually and inspection finds it early, so the inspection is scheduled;
5) Install a strainer at the inlet to keep particles from abrading the back vanes: particles accelerate the wear, so filtration protects the vanes;
6) Trend the inlet pressure and raise an alarm: the pressure drop is the precursor of cavitation, so this monitors and alarms;
7) Commission the pump and verify the flow recovers to at least 200m3/h: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include back vane wear resistance in the selection: the original absence of the feature was the root cause of the wear, so selection must always include it.
GB/T 13006-2013 Centrifugal, Mixed-Flow and Axial-Flow Pumps - NPSH