E44-026 · Hydraulic System Contamination and Stick-Slip · Electro-Hydraulic Servo Valve · ★★★
Particles >5 μm in the oil cause the valve spool to stick; position control is out of tolerance by 0.2 mm (allowable 0.05), and the system oscillates
[Sticking] Particles >5 μm embed in the orifice, raising the null-bias current.
[Oscillation] Unstable servo-loop gain causes limit-cycle oscillation.
[Design Omission] No 3 μm absolute filtration and no periodic oil testing were provided, causing sticking and out-of-tolerance.
1) Install 3 μm absolute filtration upstream of the servo valve; because particles >5 μm embed in the orifice, raising null-bias current and causing 0.2 mm out-of-tolerance, 3 μm absolute filtration keeps the spool clean;
2) Control oil contamination to within NAS level 6; because servo valves are demanding and only level 6 is stable, controlling the level preserves precision;
3) Periodically test oil particle count and water content; because both particles and water cause sticking, monitor both indicators;
4) Calibrate the servo valve null bias off-line; because null-bias drift causes position out-of-tolerance, periodic calibration re-zeroes it;
5) Seal the tank and add a desiccant breather; because open tanks collect dust and absorb moisture, sealing keeps oil clean;
6) Filter new oil to the target level before filling; because unfiltered new oil is contaminated, fill only to spec;
7) Commission to verify position accuracy≤0.05 mm (actual 0.2); because restored accuracy means stable servo, this accepts the result;
8) Write the filtration rating into the servo-system specification; because the original lack of 3 μm filtration is the root cause of sticking, the specification enforces control.
GB/T 15623-2016 Electro-hydraulic servo valves - Technical conditions