E44-856 · Throttling Noise and Vibration · Throttling valve · ★★
A DN100 throttling valve with no silencer had an outlet noise of 96dB(A), exceeding the GB12348 plant boundary of 85dB(A)
[Mechanism] The high-speed air flow at the throttling valve outlet radiates broadband noise directly; with no silencing measure the plant boundary exceeds the limit.
[Calculation] Sound power Lw=10lg(Q²Δp²)+C, and the outlet at 96dB(A) exceeds the 85dB(A) plant boundary by 11dB.
[Design Omission] No silencer installed, no sound insulation, no sound-level verification.
1) Install a silencer (resistive, insertion loss ≥15dB to bring the outlet ≤80dB(A)), since the original bare valve at 96dB(A) exceeded the plant boundary, thus installing a silencer cuts the noise;
2) Verify the sound level (plant boundary ≤85dB(A)), since exceeding it violates limits and verification meets them, thus verifying sound;
3) Choose a resistive silencer (for the mid-high frequencies), since high frequency transmits and the choice cuts it, thus selecting the type;
4) Add a sound-insulating enclosure (wrap the valve body, insulation ≥10dB), since outward transmission makes noise and the enclosure insulates, thus insulating sound;
5) Monitor the noise (sound-level meter at the outlet, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw per GB/T3767), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the opening to steady it (operate ≥30%), since changing conditions make noise and control steadies it, thus controlling the opening;
8) Write the silencer installation and sound verification into the specification, since the original lack of installation is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.
GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure