E44-857 · Throttling Noise and Vibration · Pipeline · ★★★
The pipe section after the throttling orifice excited the piping natural frequency, giving a wall amplitude of 0.8mm with weld cracking
[Mechanism] Throttling produces periodic pressure pulsation, and when its frequency coincides with the piping structural natural frequency it triggers piping resonance.
[Calculation] Pulsation frequency f=St·v/d, piping natural frequency fn=√(k/m); when the frequency difference <5% the amplitude is amplified by Q>10, causing cracking.
[Design Omission] No frequency avoidance, no denser supports, no vibration test.
1) Avoid the resonance frequency (change the throttling location or the supports so the pulsation frequency deviates from the piping natural frequency by ≥30%), since the original close frequency caused pipe vibration and cracking, thus avoiding the frequency prevents cracking;
2) Verify the natural frequency (calculate the piping fn and arrange the frequencies to avoid each other), since close frequencies crack and verification avoids it, thus verifying the frequency;
3) Add denser supports (reduce the pipe clamp spacing from 6m to 3m for stiffness), since sparse vibrates and dense suppresses it, thus densifying;
4) Add damping (a rubber damping layer at the pipe clamps), since oscillation vibrates and damping cuts it, thus adding damping;
5) Monitor the vibration (measure the pipe-wall amplitude, alarm >0.3mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (excite and measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the resonance peak, thus testing vibration;
7) Control the flow to steady the speed (limit v≤12m/s), since changing conditions drift the frequency near the natural one and steadying moves it away, thus controlling speed;
8) Write the frequency avoidance and densification into the calculation sheet, since the original lack of avoidance is the root cause of vibration and locking it in closes the loop, thus controlling it in the calculation.
GB/T 11349.1-2006 Mechanical vibration and shock