E44-294 · Valve Selection and Internal Leakage · Globe valve J41H-16 DN50 · ★★
With the upper stop lost, the stem bottomed out so the plug could not seat down; opening was only 70% and flow was insufficient.
[Bottomed] A too-long stem hits the gland at full open, leaving the plug suspended.
[Lack of Opening] The suspended plug cuts the flow area and starves flow.
[Design Omission] Stem travel and stop were not checked and a full-open trial was not run — the globe valve bottomed out.
1) Size the stem length to the travel and set an upper stop; the original was too long and bottomed out, leaving the plug suspended at only 70% opening, so stop it at full open;
2) Mark the full-open turns at assembly against over-tightening; over-tightening bottoms it out, so turn by the count;
3) During commissioning, measure full-open flow to confirm it is reached; insufficient opening is hard to notice, so verify flow;
4) Switch to a rising stem to see the full-open position; a non-rising stem is hard to judge, so use a rising stem;
5) Mark the plug travel; suspension is a hidden hazard, so mark it;
6) Periodically check for bottoming and the stop; wear shifts position, so check the position;
7) Choose a valve with generous travel margin; little margin bottoms out easily, so keep margin;
8) Bring travel check into assembly; the unchecked length was the cause of bottoming, so gate assembly.
GB/T 12235-2007 Steel globe valves and lift check valves for petroleum, petrochemical and related industries