E44-293 · Valve Selection and Internal Leakage · Swing check valve H44H-16 DN100 · ★★
A small bore made the velocity v=6m/s exceed the allowable; cavitation noise of 92dB followed the disc, and the body vibrated.
[Speed] The small bore makes v=Q/A exceed the allowable, throttling into cavitation.
[Noise] Collapsing cavitation bubbles produce 92dB.
[Design Omission] The bore was not sized by flow and the velocity was not checked — the check valve cavitated.
1) Oversize the bore to v≤3m/s; the original v=6 exceeded the limit and cavitated at 92dB with body vibration, so slow it down;
2) Check Cv so the operating opening is mid-range; off-center opening throttles, so match Cv;
3) Add a downstream diffuser to stabilize the flow; the vena contracta scours and howls, so diffuse;
4) Add a damping layer on the body to cut noise; noise travels through the body, so insulate it;
5) Periodically measure velocity to check for over-speed; over-speed causes erosion, so monitor it;
6) Switch to a low-resistance swing type to cut throttling; lower resistance erodes less, so change type;
7) Add supports and hangers against vibration; vibration travels into the pipe, so anchor it;
8) Bring velocity into selection; the unchecked speed was the cause of erosion, so gate it at design.
GB/T 12236-2018 Steel swing check valves for petrochemical industry