E44-829 · Piping Supports and Thermal Expansion · Hot State · ★★
No hot-state re-tightening, loosening, displacement deviation
[Mechanism] Without hot-state re-tightening, the bolts loosen and the displacement deviates.
[Calculation] Without re-tightening, the hot-state displacement deviates >5mm and the flange leaks.
[Design Omission] No re-tightening and no marking were provided — so re-tightening must be done.
1) Re-tighten the support in the hot state (raise to the working temperature and re-tighten the bolts): because the original lack of re-tightening deviated the hot-state displacement >5mm and leaked the flange, hot re-tightening stabilizes the position;
2) Mark the cold-state position (mark a cold-state datum to prevent error): because guesswork deviates and marking makes it clear, the position is marked;
3) Check the thermal displacement (verify the actual displacement vector): because an error causes deviation and the check corrects it, the displacement is checked;
4) Monitor the loosening condition (torque / displacement monitoring, alarm on looseness): because progressive loosening widens the deviation and early awareness helps, loosening is monitored;
5) Perform a hot test (raise and lower the temperature and record the displacement): because the original lack of testing left the loosening undiscovered, the test identifies the displacement, so the hot test is run;
6) Control the temperature ramp rate (≤30℃/h): because a rapid change loosens and a slow one keeps it under control, the rate is controlled;
7) Carry out periodic re-tightening (re-tighten every cycle): because progressive loosening causes deviation and periodic checks prevent it, the tightness is checked;
8) Write the hot re-tightening and position marking into the operation card: the original lack of re-tightening was the root cause of the loosening, so operations control the work and the hot state stays tight.
GB/T 20801.3-2020 Design code for industrial metallic piping