E44-787 · Piping Supports and Thermal Expansion · Spring hanger · ★★
Spring load lost, pipe sag >30mm, load released
[Mechanism] Wrong spring selection or preload lets the load release and the pipe sag.
[Calculation] A wrong load setting makes the sag >30mm and the spring unhook and lose its support.
[Design Omission] The load was neither selected nor the preload set — so selection must be made.
1) Reselect the spring load (size it at pipe weight ×1.2 with the operating load matched): because the original load loss made the pipe sag >30mm and the spring unhook and stop carrying, reselecting restores the support;
2) Set the spring preload (at cold state, adjust to the load marked on the scale): because a loose spring sags and setting it carries the load, the preload is set to restore the load;
3) Verify the load match (weigh the pipe and compare it with the spring chart): because a mismatch sags and verification makes it accurate, the load is verified;
4) Monitor the spring condition (read the pointer / measure the displacement, alarm on unhooking): because gradual load loss spreads the sag and early awareness helps, the spring is monitored;
5) Prevent overload unhooking (limit the load ≤ the spring's upper rating): because excess unhooks and limiting protects, the load is limited;
6) Run a load test (apply load and record the spring's displacement curve): because the original lack of testing left the loss undiscovered and the test reveals the load point, the load is verified;
7) Keep the pipe weight steady (distribute it evenly between supports to reduce each spring's load): because changing conditions release the load and evening out steadies it, the weight is steadied;
8) Write the load selection and the preload setting into the assembly card: the original lack of selection was the root cause of the load loss, so assembly controls it and the weight is always carried.
GB/T 17116.1-2018 Pipe supports and hangers