Knowledge Base › Fluid Systems Error Case › Low Condenser Vacuum Causes Insufficient Heat Transfer

Low Condenser Vacuum Causes Insufficient Heat Transfer

E44-504 · Heat-Exchanger Fouling and Insufficient Heat Transfer · Condenser (Shell-and-Tube) · ★★

Problem Description

Vacuum of -0.085MPa is low, terminal difference rises 8℃, exhaust temperature is high, and unit output drops.

Root Cause

[Mechanism] Tube-wall scale and air in-leakage worsen heat transfer and let noncondensables accumulate.
[Calculation] A K drop raises the terminal difference Δt=Q/(mcp) by 8℃ and drops vacuum by 0.01.
[Design Omission] No leak detection, no scale removal, and no noncondensable extraction were provided, leading to insufficiency.

Corrective Solution

1) Detect and plug leaks to prevent air in-leakage (He leak test / hydrotest), since in-leakage lets noncondensables accumulate, dropping vacuum from -0.095 to -0.085MPa and raising terminal difference 8℃, thus plugging leaks to restore vacuum;
2) Chemically remove tube-side scale to restore K (every 2 years; wash at Δp>0.1MPa), since scale lowers K, raises terminal difference 8℃, and raises exhaust temperature, thus removing scale to restore K;
3) Increase noncondensable extraction (up-size ejector / two-stage), since accumulated noncondensables worsen the heat-transfer film and raise the terminal difference, thus strengthening extraction to preserve vacuum;
4) Verify circulating-water flow is sufficient (size summer temperature-rise margin ≥15%), since insufficient water raises the terminal difference Δt=Q/(mcp) and exhaust temperature, thus providing enough water to cool;
5) Provide terminal-difference alarm (alarm if terminal diff > design +5℃), since fouling / air leakage first raises the terminal difference, ahead of output drop, thus alarming on it;
6) Continuous sponge-ball cleaning (ball recovery ≥95%), since scale thickens and balls scrub it off to restore α, thus suppressing scale by continuous cleaning;
7) Schedule vacuum-system inspection (monthly leak check / pump performance), since gradual leakage slowly lowers vacuum, thus inspecting on schedule to preserve vacuum;
8) Write leak detection and scale removal into the condenser procedure, since the original design omitted leak finding and noncondensable extraction, the root cause of low vacuum, thus controlling by procedure.

Checklist

Reference

GB/T 151-2014 Heat exchangers