E44-505 · Heat-Exchanger Fouling and Insufficient Heat Transfer · Falling-Film Evaporator · ★★
The heating chamber fouls, steam output drops 20%, steam consumption rises, and operating cycle is short.
[Mechanism] Process liquor fouls the heating surface, raising Rf.
[Calculation] Rf=0.3 cuts K by 30%, and steam output Q=KAΔTm drops 20%.
[Design Omission] The concentration ratio was not controlled and no scheduled cleaning was set, leading to fouling.
1) Control the concentration ratio (specific gravity ≤ process upper limit) to prevent over-concentration scaling, since over-ratio liquor crystallizes on the wall, Rf=0.3 cuts K by 30% and steam output Q=KAΔTm drops 20% with steam consumption rising; thus controlling the ratio suppresses crystallization, restores K, and protects steam output;
2) Schedule acid cleaning for scale removal (each batch / at Δp>0.1MPa), since accumulated scale lowers K and shortens the cycle, thus acid-cleaning on schedule to restore flow area;
3) Preheat the feed (temperature entering the heating chamber ≥ below the crystallization point), since cold feed causes local supercooling, crystallization, and wall adhesion, thus preheating to even out temperature and suppress crystallization;
4) Monitor steam output (alarm if output < 80% of design), since fouling lowers K first as a drop in steam output, ahead of cycle collapse, thus alarming on output;
5) Add antiscalant dispersant (dosed by calcium concentration), since crystal nuclei adhere to the wall and the dispersant suppresses crystallization, thus inhibiting scale and adhesion;
6) Optimize the operating cycle (shorten single pass, set cleaning interval), since scale limits the cycle and long cycles worsen it, thus optimizing to extend the cycle;
7) Raise heating-chamber velocity (≥1.2m/s), since process liquor settles and adheres in low-velocity zones, thus raising velocity to cut residence time and suppress settling;
8) Write ratio control and scale washing into the evaporator procedure, since the original design omitted concentration control and scheduled cleaning, the root cause of fouling, thus controlling by procedure.
GB/T 151-2014 Heat exchangers