E44-278 · Valve Selection and Internal Leakage · Ceramic ball valve Q41TC-16 DN50 · ★★★
Hard particles in the medium wedged in and fractured the ceramic seat, causing high-pressure injection leakage; fragments jammed the stem.
[Fracture] Hard particles wedge into the ceramic-to-metal gap, concentrating stress and cracking the brittle ceramic.
[Injection] After cracking, the high-pressure medium jets out along the fissure.
[Design Omission] A brittle hard ceramic was wrongly chosen for a particle-laden medium, with no strainer upstream — the ceramic valve cracked.
1) Fit an upstream strainer (accuracy ≤50μm) for particle-laden media; wedging particles fractured the brittle ceramic and caused injection leakage, so clean the medium to protect the valve;
2) For this service switch to a metal hard seat rather than ceramic; ceramic fears particle wedging while metal yields, so avoid cracking;
3) Add elastic backing under the ceramic part to relieve stress concentration; hard-on-hard cracks easily, so cushion it;
4) Use a quick-replaceable seat for easy post-damage exchange; once cracked the seat must be replaced, so make it renewable;
5) Periodically inspect the ceramic for cracks; cracks start as micro-flaws, so diagnose early;
6) Control the medium velocity to cut impact; high-velocity particles strike hard, so slow it;
7) Add downstream venting against injection hazards; injection leakage is dangerous, so make it bleedable;
8) Include medium cleanliness in valve selection; the uncontrolled particles were the cause of cracking, so gate it at design.
GB/T 12237-2007 Steel ball valves for petroleum, petrochemical and related industries