E44-317 · Excessive Pipe Resistance and Pressure Drop · Only 3D straight run at a DN100 pump suction · ★★
A straight run of only 3D swirls the suction, raising local loss to ζ=1.5, dropping NPSHa by 0.3m, and adding resistance with cavitation.
[Swirl] A short straight run leaves the flow unsteady, swirling at the suction and raising ζ.
[NPSH Drop] Swirl makes the suction pressure fluctuate, causing cavitation and added resistance.
[Design Omission] No ≥5D straight run left and no suction check — straight run too short.
1) Provide a suction straight run ≥5D (here ≥500mm), since only 3D gave swirl, ζ=1.5, and a 0.3 NPSHa drop — thus calming flow to cut ζ;
2) Fit a flow straightener before the suction, since unsteady turbulence loses — thus straightening;
3) Include suction local loss in NPSHa, since swirl lowers NPSH and causes cavitation and added resistance — thus accounting for all loss;
4) Do not point an elbow straight at the suction, since a direct approach swirls badly — thus offsetting it;
5) Enlarge the suction bore to lower v, since high velocity amplifies swirl — thus upsizing;
6) Add suction-pressure monitoring, since swirl causes fluctuation — thus watching pressure;
7) Feed a double-suction pump symmetrically, since offset feeding swirls — thus centering it;
8) Write the straight-run requirement into the layout, since the original layout was too short — thus locking it in at layout.
GB/T 20801.3-2020 Design code for industrial metallic piping