E44-723 · Hydraulic System Contamination and Crawling · Hydraulic motor · ★★
Crawling, shuddering, unstable rotation
[Mechanism] The motor crawls.
[Calculation] Unstable pressure causes the crawling.
[Design Omission] No pressure stabilization, no venting, and no inspection were provided, so the supply is not steady.
1) Steady the supply pressure (relief valve + accumulator, fluctuation ≤0.3MPa), because the original unstable pressure made the output rotation uneven and caused crawling, thereby steadying the pressure and preventing the crawling;
2) Vent the motor (casing vent, idle running), because air ingress causes crawling and venting clears it, thereby excluding air;
3) Even out the load (uniform distribution, variation ≤10%), because an unbalanced load causes crawling and evening it aligns the motion, thereby steadying the load;
4) Clean the port plate against sticking (disassemble and flush, remove particles), because sticking causes crawling and cleaning restores flow, thereby restoring rotation;
5) Keep the oil clean (NAS9), because contamination causes sticking and control prevents it, thereby reducing the sticking;
6) Monitor the crawling (speed sensor, alarm on shuddering), because gradual crawling is invisible and monitoring catches it, thereby giving early warning;
7) Limit the low speed (≥10% of rated), because a very low speed causes crawling and limiting avoids it, thereby steadying the speed;
8) Write the pressure stabilization and venting into the maintenance card (motor venting record), because the missing stabilization was the root cause of the crawling and freezing it into the maintenance card enforces control.
GB/T 3766-2015 General technical conditions for hydraulic systems