E44-463 · Filter Clogging and Contamination · Parallel Filters 2 Units · ★★
Resistance mismatch between two parallel filters caused flow maldistribution; one plugged at Δp=0.18MPa while the other saw only 0.03MPa and was underused, reducing total filtration capacity.
[Mechanism] Unequal resistance in the inlet/outlet headers biases flow between the two legs.
[Calculation] Branch resistance difference Δξ gives a flow ratio Q1/Q2=√(ξ2/ξ1)=3; one plugs while the other idles, and total efficiency drops 40%.
[Design Omission] Piping was not symmetric and branch balance was not checked, causing maldistribution.
1) Arrange inlet and outlet piping symmetrically so ξ1≈ξ2, because the original resistance mismatch gave a Q ratio of 3, one leg plugged while the other idled and efficiency fell 40%, thereby equalizing flow symmetrically;
2) Add a balancing valve on each branch to equalize Q, because bias means uneven flow, thereby adjusting to equality;
3) Fit a Δp gauge on each chamber to monitor bias, because maldistribution shows on the gauges, thereby monitoring bias;
4) Size each unit so the other can take full flow when one plugs, because that is the purpose of parallel arrangement, thereby providing mutual backup;
5) Enlarge header diameter to reduce resistance mismatch, because small headers amplify the difference, thereby upsizing;
6) Periodically swap the two chambers' positions, because dirt accumulates unevenly, thereby swapping;
7) Verify total filtration capacity per single unit, because bias reduces the total, thereby sizing per unit;
8) Write balance into the piping design, because the original asymmetry is the root cause of maldistribution, thereby enforcing piping control.
GB/T 26114-2010 Filters for liquid filtration