E44-462 · Filter Clogging and Contamination · High-Temperature Filter 304 · ★★★

Problem Description

Under high-temperature service, the 304 screen suffered intergranular corrosion and perforation; outlet debris was 0.4%, short-circuit failure occurred, and downstream valves jammed.

Root Cause

[Mechanism] Overservice temperature depletes chromium at grain boundaries, causing pitting and perforation.
[Calculation] Service at 450℃ exceeds 304's 400℃ limit, corrosion rate rises 3×, and a 2mm hole causes 8% bypass.
[Design Omission] Material was not selected by medium temperature; 304 was misused, causing perforation leakage.

Corrective Solution

1) Change to 310S material rated for 650℃, because the original 304 exceeded 400℃, corroded through and outlet was 0.4%, thereby withstanding temperature against perforation;
2) Select filter media by medium temperature with margin, because over-temperature causes corrosion, thereby selecting by temperature;
3) Apply post-weld solution treatment to prevent chromium depletion, because chromium depletion causes pitting, thereby solution-treating;
4) Add outlet particle monitoring, because perforation is measurable, thereby monitoring particles;
5) Add external housing temperature measurement with interlock shutdown, because over-temperature damages material, thereby interlocking;
6) Cool the medium to within material limits before filtration, because heat exceeds limits, thereby cooling;
7) Specify thickness ≥1.5mm against thin-wall perforation, because thin sections perforate easily, thereby increasing thickness;
8) Write temperature resistance into the selection, because the original wrong material is the root cause of perforation, thereby enforcing selection control.

Checklist

Reference

GB/T 26114-2010 Filters for liquid filtration