E44-461 · Filter Clogging and Contamination · Water Filter 50μm · ★★
Biofilm grew on the filter face, flux fell, Δp=0.12MPa > 0.05, total plate count was 1×10⁵ > 100, and water quality deteriorated.
[Mechanism] Nutrient-laden water lets biofilm attach to the filter face and occupy the flow channels.
[Calculation] Growing film thickness shrinks the effective pore diameter by 40%, v=Q/A rises, and Δp=ξρv²/2=0.12MPa.
[Design Omission] No chlorination and no scheduled flushing were provided; biofilm caused the blockage.
1) Chlorinate upstream so residual chlorine is 0.3mg/L to suppress the film, because there was no suppression, biofilm occupied channels and Δp was 0.12, thereby suppressing the film and lowering Δp;
2) Schedule a weekly backwash and drain the film, because biofilm grows progressively, thereby weekly flushing;
3) Change to antibacterial silver-ion media, because the original media attached easily, thereby making it antibacterial;
4) Measure total plate count at the outlet, because exceeding 1×10⁵ indicates contamination, thereby monitoring;
5) Add UV disinfection in the filter housing as an aid, because light suppresses the film, thereby assisting disinfection;
6) Reduce residence time to prevent film growth, because long contact lets it grow, thereby flowing faster;
7) Rotate and disinfect spare elements, because a single element is hard to clean, thereby rotating;
8) Write film suppression into the water-quality procedure, because the original lack of suppression is the root cause of biofilm, thereby enforcing procedural control.
GB/T 26114-2010 Filters for liquid filtration