Candle Filter Back-Pulse Pressure Insufficient

E44-464 · Filter Clogging and Contamination · Candle Filter Porous · ★★

Problem Description

Back-pulse air pressure was only 0.2MPa, insufficient to slough the cake; Δp rose to 0.3MPa, cleaning intervals shortened, and residue discharge was poor.

Root Cause

[Mechanism] Low back-pulse pressure fails to overcome cake adhesion to the candle surface.
[Calculation] Cake removal requires reverse Δp > the adhesion-equivalent 0.4MPa; the original 0.2MPa overcomes only 30%, and residual Δp=0.3.
[Design Omission] Back-pulse pressure was not checked against adhesion; low pressure left the cake attached.

Corrective Solution

1) Raise back-pulse pressure to 0.45MPa to overcome adhesion, because the original 0.2 overcame only 30% and Δp was 0.3, thereby sloughing the cake with adequate pressure and lowering Δp;
2) Enlarge the back-pulse tank volume to sustain the instantaneous flow, because small volume drops pressure, thereby sustaining flow;
3) Use fast-opening back-pulse valves to shorten pulse time, because slow opening is less effective, thereby fast-opening;
4) Set a residual Δp alarm at 0.3MPa, because exceeding it shortens intervals, thereby alarming;
5) Adjust slurry concentration before filtration to prevent a thick cake, because a thick cake is hard to slough, thereby adjusting concentration;
6) Coat the candle surface with filter aid for easy sloughing, because bare surface sticks, thereby coating with aid;
7) Periodically check the air-source pressure, because a weak source weakens the pulse, thereby checking the source;
8) Write back-pulse pressure into the operation, because the original low pressure is the root cause of failure to slough, thereby enforcing operational control.