Knowledge Base › Fluid Systems Error Case › Siphon Suction Causing Cavitation

Siphon Suction Causing Cavitation

E44-921 · Siphon and Backflow · Siphon Pipe · ★★

Problem Description

Suction dry-out, cavitation, damage

Root Cause

[Mechanism] The negative pressure at the siphon top is too low, below the medium's vapor pressure, so the liquid vaporizes and is drawn off, causing cavitation.
[Calculation] The top absolute pressure = 10.3 - h_v; at h_v=10.0 m the absolute pressure of 0.3 m approaches the vapor pressure of 0.24 m, vaporizing the liquid and drawing it off.
[Design Omission] h_v was not checked, the back pressure was not raised, and the suction lift was not reduced.

Corrective Solution

1) Check h_v≤9.0 m so the top absolute pressure is ≥1.3 m (originally 10.0 m, close to vaporization), because an absolute pressure > the vapor pressure prevents vaporization and eliminates the dry-out, thereby suppressing cavitation;
2) Provide a back-pressure air makeup pipe at the top (break the vacuum and raise the pressure to 0.5 m), because makeup air raises the absolute pressure away from the vaporization point, thereby preventing dry-out;
3) Reduce the suction lift H_lift from 10.5 m to 8.5 m, because h_v falls with H_lift and the top pressure rises, thereby reducing vaporization;
4) Improve the medium temperature control (a 5℃ drop lowers the vapor pressure by 0.1 m), because a lower temperature lowers the vapor pressure and makes avoidance easier, thereby controlling the temperature to suppress cavitation;
5) Fit the top with a vacuum gauge and alarm (alarm when h_v>9.0 m), because approaching vaporization first shows as a high vacuum and allows early intervention, thereby monitoring the vacuum to prevent cavitation;
6) Perform a cavitation test (head drop ≤3% is acceptable), because cavitation directly shows as a head drop and the test confirms it, thereby verifying the margin from the head;
7) Raise the inlet level 0.5 m (reducing H_lift), because a higher inlet means a smaller suction lift and a higher top pressure, thereby reducing vaporization;
8) Write the h_v≤9.0 m check into the design regulations, because the root cause of dry-out is h_v close to vaporization, so the regulations must govern to prevent cavitation.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping