E44-920 · Siphon and Backflow · Purified-Water Piping · ★★★
Backflow, purified-water contamination, mixing
[Mechanism] The purified-water pipe is cross-connected to the process-water pipe, and an elevation difference or a pump stop lets the process water backflow into the purified-water pipe.
[Calculation] A differential pressure of 0.08 MPa drives the backflow at v≈0.6 m/s, contaminating the purified water at 0.3 m³/h and exceeding the limit in 1 h.
[Design Omission] The purified-water pipe had no check valve, no differential-pressure check, and no water-quality monitoring.
1) Install double check valves at the purified-water pipe inlet (in series, each with seepage ≤1 mL/min), because the failure of a single valve requires double insurance for the demanding purified water, thereby reliably isolating the process water;
2) Check that the purified-water side pressure is always ≥ the process side by 0.05 MPa (originally 0.08 MPa lower), because a positive differential pressure eliminates the reverse driving force, thereby preventing backflow by design;
3) Install an online conductivity meter downstream of the connection (shut off on alarm >0.1 μS/cm), because contamination of the purified water first shows as a conductivity rise before the whole pipe, thereby intercepting it early;
4) Use PN16 flanges with high-purity sealing on the purified-water pipe (0.6 MPa airtightness), because slight leakage causes slow cross-contamination and high-purity sealing stops the seepage, thereby preventing seepage contamination;
5) Perform a backflow test (open the valve and check the purified-water conductivity), because the design omitted the difference check and the test confirms the isolation effect, thereby verifying the isolation;
6) Control the operating differential pressure ≥0.05 MPa with an alarm (adjust the pump if lower), because a stable difference prevents backflow and controlling it prevents contamination, thereby preventing mixing in operation;
7) Provide nitrogen blanketing on the purified-water tank (0.02 MPa), because the blanket maintains positive pressure and eliminates negative-pressure back-suction, thereby keeping the purified water pressurized;
8) Write the double check valves and differential-pressure checking into the purified-water regulations, because the root cause of backflow is a reversed difference without isolation, so the regulations must govern to prevent purified-water contamination.
GB/T 20801.3-2020 Design code for industrial metallic piping