Water Hammer from Broken Siphon Flow

E44-364 · Water Hammer and Pressure Surge · Siphon pipe, inlet flow break · ★★

Problem Description

A break in siphon inlet flow caused liquid-column separation; on refilling the water hammer Δp=1.0MPa exceeded the allowable limit and the pipe buckled.

Root Cause

[Mechanism] A broken siphon separates the liquid column, and the collision on refilling generates hammer.
[Calculation] The negative-pressure wave buckled the thin wall.
[Design Omission] The siphon was not kept full and no vacuum valve was provided, leaving the siphon to suffer hammer.

Corrective Solution

1) Fit a foot valve at the siphon inlet to keep it full and prevent flow break, because the break separated the column and the refill Δp=1.0 exceeded the limit and buckled the pipe; hence kept full;
2) Install a vacuum breaker at the high point to slow refilling, because the refill collision generates hammer; hence slow refill;
3) Raise the pipe rating to resist negative waves, because negative pressure buckles it; hence higher rating;
4) Check the liquid-column separation condition, because low head makes separation likely; hence separation check;
5) Close first and then stop the pump, because a direct stop breaks the siphon; hence close first;
6) Install a surge arrester to cut the refill wave, because refilling generates hammer; hence peak absorption;
7) Recheck by water-hammer simulation, because hidden peaks are hard to spot; hence simulation;
8) Write siphon protection into the design, because the lack of keeping it full was the root cause of the hammer; hence design control.

Checklist

Reference

GB/T 32284-2015 Code for design of pump stations - Water hammer protection