E44-337 · Excessive Piping Resistance and Pressure Drop · Instrument air duct at v=15m/s · ★★
A low-pressure air duct at v=15m/s exceeds the recommended 8; pressure drop is 0.05kPa/m and total friction loss 0.3kPa, leaving the end under-pressured
[Mechanism] v=15 exceeds the recommended 8, raising loss per unit length and noise.
[Calculation] The 0.3kPa friction loss leaves the end under-pressured.
[Design Omission] No large bore chosen for low-pressure air and no v control - high v kept resistance high.
1) Upsize the bore to v≤8m/s, since 15 over 8 caused 0.05/k·m loss, 0.3 total, and an under-pressured end, lowering v;
2) Size the low-pressure air duct by the recommended velocity, since low-pressure air suits low v, sizing by recommendation;
3) Check friction loss with margin, since it accumulates over length, leaving margin;
4) Add an air receiver to stabilize pressure, since the end pressure fluctuates, stabilizing it;
5) Cut elbows to lower local loss, since local losses stack, reducing bends;
6) Raise compressor pressure to make up loss, since the end needs pressure, adding pressure;
7) Periodically check for air leaks, since leaks act as equivalent resistance, hunting leaks;
8) Write the air velocity into the design, since the missing control was the root cause of resistance, closing the loop at design.
GB/T 20801.3-2020 Design code for industrial metallic piping