E44-338 · Excessive Piping Resistance and Pressure Drop · 6 units on one header with failed staggering · ★★
Failed staggering logic starts 4 units at once; instantaneous Q=2.5×, hf=0.35MPa exceeds 0.12, and pressure drops after the valve
[Mechanism] Failed staggering starts several units together, Q=2.5×.
[Calculation] hf=0.35 exceeds 0.12, dropping pressure after the valve.
[Design Omission] No interlocked staggering and no simultaneous-start check - the staggering failed.
1) Set a PLC interlock to force a stagger interval ≥10s, since the failure started 4 units together, Q=2.5, hf=0.35 over 0.12, locking the peak;
2) Check hf for the worst simultaneous start with margin, since simultaneous start causes overload, leaving margin;
3) Upsize the header to carry the peak, since the peak Q is large, upsizing it;
4) Add a buffer tank to smooth the transient, since the peak is sudden, buffering it;
5) Interlock pressure monitoring to stop/start, since pressure drop is hazardous, monitoring and tripping;
6) Drive pumps on VFD to follow the peak, since fixed speed overloads, using variable speed;
7) Periodically test the simultaneous-start probability, since the logic drifts, measuring the probability;
8) Write the stagger interlock into the control, since the missing interlock was the root cause, closing the loop at control.
GB/T 20801.3-2020 Design code for industrial metallic piping