E44-336 · Excessive Piping Resistance and Pressure Drop · Pump-outlet hose not clamped · ★★
Discharge-pipe vibration loosens joints, makes the section flutter, fluctuates local loss up 0.04MPa, and leaks the seal
[Mechanism] Unsecured, the pipe vibrates, its section flutters, and the flow turns turbulent.
[Calculation] The fluctuating local loss rises 0.04MPa, accompanied by leakage.
[Design Omission] No pipe clamp and no vibration isolation - the outlet vibrated.
1) Secure the discharge pipe with clamps and anti-vibration pads, since the unsecured pipe vibrated, fluttered, added 0.04 loss and leaked, securing and isolating it;
2) Add a flexible joint at the pump outlet to absorb vibration, since a rigid joint transmits it, using a flexible joint;
3) Check vibration severity ≤4.5mm/s, since above that loss and leakage follow, limiting vibration;
4) Lay out away from the resonance frequency, since resonance amplifies vibration, avoiding the frequency;
5) Periodically inspect joints for looseness and leakage, since vibration loosens them, inspecting joints;
6) Add support brackets to cut the overhang, since cantilevers vibrate easily, supporting the pipe;
7) Include the local loss in the total resistance, since the loss fluctuates, accounting for it fully;
8) Write securing and isolation into the installation, since the missing fixing was the root cause, closing the loop at installation.
GB/T 20801.3-2020 Design code for industrial metallic piping