E44-708 · Hydraulic System Contamination and Crawling · Pipe Fitting · ★★
Loosening, external leakage, seepage
[Mechanism] Loosening causes external leakage.
[Calculation] Loosening causes seepage.
[Design Omission] No tightening, no inspection, and no anti-loosening provision - a design defect leading to loosening.
1) Tighten fittings to torque (torque per specification, recorded); the original loose fitting seeped oil >1 drop/min and lost pressure, so retightening stops the leakage;
2) Add spring washers to prevent loosening (jam-nut tightening, lock); vibration causes loosening, so spring washers lock the joint;
3) Select qualified seals (fluororubber O-rings, correct size); wrong seals cause seepage, so correct selection keeps the seal;
4) Check for leakage (visual + leak-detection fluid; retighten at any seepage); gradual loosening is invisible, so inspection catches it early for early warning;
5) Clean the faces and remove damage (lapped flange faces, no scratches); damaged faces cause seepage, so cleaning and flattening preserves the seal;
6) Control vibration to prevent loosening (anti-vibration pads, fixed supports); vibration causes loosening, so control stabilizes the joint;
7) Schedule monthly fitting inspection (torque sampling); gradual loosening is invisible, so scheduled inspection makes it measurable;
8) Write fitting tightening and anti-loosening into the assembly card (torque record); since lack of tightening was the root cause of loosening, fixing it in assembly gives assembly oversight.
GB/T 3766-2015 General technical conditions for hydraulic systems