E44-1120 · Miscellaneous · Packing · ★★
Leak, seepage, contamination
[Mechanism] The packing gland was not evenly compressed and the packing aged, so the shaft seal seeps.
[Calculation] Gland-bolt tightening is uneven by 30%, packing contact pressure is only 8MPa (should be ≥15), and seepage is 5 drops/min.
[Design Omission] No even compression, no suitable packing material, no preload control, and no tightness test.
1) Even up the gland (tighten diagonally), since looseness causes leakage and even compression seals, restoring tightness;
2) Fit suitable packing (graphite for asbestos), since aged packing leaks and suitable material seals, preventing leakage;
3) Control the preload (contact pressure ≥15MPa), since looseness seeps and compression seals, sealing tightly;
4) Check shaft finish (Ra≤0.8), since roughness leaks and a smooth finish seals, giving a good shaft seal;
5) Run a tightness test (seepage ≤1 drop/min), since without proof tightness is unknown and a measured test confirms it, setting tightness on data;
6) Fit seepage monitoring (alarm on wetness), since leakage first shows as seepage for early warning, monitoring leakage;
7) Set a replacement interval (quarterly), since long service leaks and scheduled replacement prevents it, guarding against leakage in service;
8) Write even compression and suitable material into the packing card, since leakage stems from uneven gland plus aged packing, closing the loop on the card.
GB/T 5894-2008 Mechanical seals