E44-732 · Uneven Flow Distribution · Reactor · ★★
Feed maldistribution, reaction variation
[Mechanism] Uneven feed makes the reaction vary.
[Calculation] The maldistribution causes the reaction variation.
[Design Omission] No distribution, no verification, and no inspection were provided, so the feed distribution is wrong.
1) Provide a feed distributor (ring header + nozzles, uniform distribution), because the original uneven feed made the concentration differ by >15% between points and varied the reaction, thereby distributing the feed evenly;
2) Verify the flow of each port (calibrate each port, deviation ≤3%), because a difference makes the distribution uneven and verification restores accuracy, thereby verifying the flows;
3) Standardize the feed pipe diameters (same diameter on each feed, deviation ≤3%), because a diameter difference causes deviation and standardization evens it, thereby standardizing the diameters;
4) Monitor the distribution (sample at each point, alarm above a 10% difference), because gradual maldistribution is invisible and monitoring catches it, thereby giving early warning;
5) Keep the total feed steady (stable pump frequency, fluctuation ≤2%), because changing conditions cause maldistribution and control steadies them, thereby steadying the feed;
6) Run a feed test (dye visualization, accept when even), because the lack of testing caused the maldistribution and testing verifies it, thereby testing the feed;
7) Clear the ports against blockage (clean at fixed intervals, remove deposits), because blockage makes the distribution uneven and cleaning restores flow, thereby clearing the ports;
8) Write the distribution and flow verification into the specification (distribution uniformity), because the missing distribution was the root cause of the feed maldistribution and freezing it into the specification enforces control.
GB/T 20801.3-2020 Design code for industrial metallic piping