Tray Liquid Flow Maldistribution

E44-733 · Uneven Flow Distribution · Tray · ★★

Problem Description

Liquid maldistribution, efficiency loss

Root Cause

[Mechanism] Liquid maldistribution lowers the tray efficiency.
[Calculation] The maldistribution causes the efficiency loss.
[Design Omission] No liquid distribution, no verification, and no inspection were provided, so the liquid distribution is wrong.

Corrective Solution

1) Provide an even liquid distributor on the receiver tray (level tray, uniform seal), because the original liquid maldistribution lowered the tray efficiency by >10% and created flow differences, thereby distributing the liquid and evening the tray;
2) Verify the downcomer resistance (each downcomer, difference ≤5%), because a difference makes the distribution uneven and verification evens it, thereby verifying the downcomers;
3) Equalize the weir heights (outlet weir height difference ≤2mm), because a difference makes the distribution uneven and adjustment evens it, thereby adjusting the weirs;
4) Monitor the liquid condition (observe the tray surface, verify on any deviation), because gradual maldistribution is invisible and monitoring catches it, thereby giving early warning;
5) Even out the gas phase (gas distributor, uniform distribution), because a deviation makes the distribution uneven and control evens it, thereby evening the gas;
6) Run a tray-efficiency test (measure the tray efficiency, accept when even), because the lack of testing caused the loss and testing verifies it, thereby testing the efficiency;
7) Clear blockages against deviation (clean at fixed intervals, remove blockages), because blockage makes the distribution uneven and cleaning restores flow, thereby clearing the blockages;
8) Write the liquid distribution and downcomer verification into the specification (tray efficiency ≥90% of design), because the missing distribution was the root cause of the liquid maldistribution and freezing it into the specification enforces control.

Checklist

Reference

GB/T 150-2011 Pressure vessels